RadPRO D2-50RF Dynamic Digital RF System

Digital Radiography & Fluoroscopy Solutions

About RadPRO D2-50RF Dynamic Digital RF System


RadPRO D2-50RF

Specifications

Generator
  kW Output 65 kW or 80 kW
  High Frequency generator with AEC Output: 65 kW according to EN 60336 at 100 kV
Ripple rate < 1 kV at 100 kV
100 kV @ 650 mA
400 mA @ 150 kV
  Radiographic parameters From 40 to 150 kV, by step of 1 kV (or displacement in the range by slider), accuracy ± (3% + 1 kV)
From 10 to 650 mA, accuracy ± (4% + 1 mA), 19 values
(10, 12.5, 16, 20, 25, 32, 40, 50, 65, 80, 100, 125, 160, 200, 250, 320, 400, 500, 650)
From 1 ms to 10 s, accuracy ± (2% + 0.1 ms), 38 values
1, 2, 3, 4, 5, 6, 8, 10, 12, 16, 20, 25, 32, 40, 50, 65, 80, 100, 125, 160, 200, 250, 320, 400, 500, 650, 800 ms and  1, 1.25, 1.6, 2, 2.5, 3.2, 4, 5, 6.5, 8, 10 s
From 0.1 mAs to 500 mAs
  Fluoroscopy parameters From 40 to 120 kV, by step of 1 kV, accuracy ± (3% + 1 kV)
From 0.5 to 5 mA (low dose) and up to 7 mA (higher dose)
  Operating mode 3 points (kV, mA, s)
2 points (kV, mAs)
1 point (kV, AEC)
  AEC 3 chambers
 
Remote Control Table
  SID Motorized and continuous from 110 to 180 cm, 6 cm/s
  Column angulations Motorized, +/-40°, 10°/s
  Tube rotation Manual, +/-180°, with electromagnetic brake and mechanical stops every 90° that permits, with table in vertical position, to makes exposures on stretcher or on wall stand (dependant on the configuration)
 
Tomography
  Layer thickness 1.5 mm (at 40°), 3 mm (at 20°), 6 mm (at 10°)
  Maximum speeds per angle 0.5 s (10°); 1 s (20°); 2 s (40°)
 
Patient Support
  Table height 64 to 93 cm, 6 cm/s
  Table top Flat, 225x81 cm, 60 cm radio transparent
  Absorption 0,4 mm eq Al
  Patient load Dynamic weight is 500 pounds or less in any direction - Static weight is 660 pounds (between 501 and 660 pounds)
  Lateral movements Motorized, +/- 18 cm at 6 cm /s
  Longitudinal movements Motorized, +/- 50 cm (or 70/30 cm or 120/50 cm) at 10 cm /s
  Tilting -25°/+90°, 6°/s
  FPD longitudinal travel 135 cm, 14 cm/s
  Patient coverage Head to Toe, > 2.5 m
 
Grid
  Focus 110 cm and 180 cm
  Ratio 10:1, 40 l/cm
 
Table Console
  Soft keys Tube 0 position, table 0 position, longitudinal tabletop movements, lateral tabletop movements, auto-collimation, auto-positioning and lighting
  Joysticks SID, column angulations, tilting, variable height, carriage, tabletop lateral movements and collimator shutters
  IR remote control All the table movements are available
 
Touch screen
  3 table position quick access Stretcher, parking and chest
  3 fluoroscopy field zooms 14", 12", 9"
  Display Table height, angulations, SID, tilting angle, collimator size
 
Accessories
  Footrest
  Adjustable stool
  2 handles
  2 winches
  1 belt
 
X-ray Tube
  Presetting of x-ray tube features Loading ratings, cooling ratings, starting voltages, starting times, maximum current limitation
  Safety and protection disposals for x-ray tube The electronic calculation of load by software indicates limits to the tube with message and forbids x-ray emission
Housing temperature control and display of available Heat Units in %
Overheated IGBTs detection
Housing oil pressure control in series with x-ray tube heat safety
  Max exposure voltage 150 kV
  Focal spot 0.6 and 1.2 mm
  Output 40 and 100 kW
  Anode angle 12.5°
  Anode rotation 9000 rpm
  Time of anode rotation 1.6 s
  Anode dimension 102 mm
  Inherent filtration 0.7 mm
  Anode heat storage capacity 600 kHU (285kJ) Standard
800 kHU and 1000 kHU Optional
  Anode heat dissipation rate 1000 W (81,1 kHU /min; 60 kJ /min)
  House heat storage capacity 2025 kHU (1000 kJ)
  Housing heat dissipation rate 1000 W (81 kHU /min; 60kJ /min) with fan
  Cooling Air
  High Voltage cable length 12 meters
  Total filtration IEC 60-601-3 compliant
  Weight 29 kg
 
Collimator
  Inherent filtration 1 mm Al
  Copper pre-filter 0 mm - 0.1 mm - 0.2 mm - 0.3 mm motorized and automatic (pre-programmed in each protocol)
  Rotation +/-30°
  Full field light localizer 100 W halogen lamp, laser, timer
  Square collimation Motorized, manual or automatic (pre-programmed in each protocol)
 
DAP System
  Active area 147 mm × 147 mm
  Stabilization time Approximately 6 minutes
  Measuring range from 10 to 99 999 999 mGy.cm²
  Digital resolution 1 mGy.cm²
  Sensitivity uniformity < 6 %
  Accuracy +/- 25 %
  Filtration Eq Al (70 kV) 0.2 mm
  Transparency > 70 %
 
Video Camera
  Video camera Free radiation positioning
  Image display On the screen of the table console
 
Auto-Positioning
 

Complete system operation

Control of generator, table and imaging system from the acquisition console
  Examination procedure The table position, generator parameters and collimation settings, including additional filtration and image processing parameters, are automatically set via protocols
  Protocols Customizable
 
Table Auto-Positioning
  Tilting
  Column angulations
  SID
  Lateral tabletop position
  Longitudinal tabletop position
  Collimation
  Filters
 
Optional Compression
  Compression strength 0 to 130 N
  Available angulations +/-10°